A63, “Die Wertereihe
wurde geaendert”) and kept both transfers out of Amprion - 34.75 kWh to
TenneT, 5 kWh to TransnetBW. Cloover was 39.75 kWh short in Amprion.
The bridge reads every confirmation, compares it per series with what was
sent, and measures Fahrplan/Ist and the Kalkulation against the confirmed
position.
The confirmations
The TSO answers a schedule message with confirmation reports (ESSConfirmationReport):
Per series a
TimeSeriesConfirmation holds the values the TSO keeps (a
reason A63: modified), an ImposedTimeSeries one the TSO set without
us, a TimeSeriesRejection one not taken into account (counted as 0).
Governing per TSO is the newest final report, else the newest report.
Where they come from
Every 30 minutes the orchestrator reads, for each submitted day from three days back to tomorrow that is not yet final for every TSO:- Engrate’s read-back of the day: the schedules, their versions with the series as sent, and the TSO’s answers;
- the content of every confirmation not yet held - the XML as Engrate
received it (
GET /schedule-management/v1/schedules/{uid}/incoming-messages/{message_uid}); - where Engrate serves no content: Engrate’s series state (
GET /schedule-management/v1/schedules/{uid}/series-state, alpha) - the values with their finality.
cnf_<message>.xml),
the comparison in fahrplan_bestaetigung.json.
The effect on the balancing group
Only the trade series count - internal (with the trader) and external (between Regelzonen). The forecast series of production and consumption are information, not settled. Per Regelzone:+ where the series brings energy into our group in that Regelzone, −
where it takes it out. Negative means less scheduled in: the group is
short by it where the customers consume as forecast. For Amprion on
20.10: the purchase −39.75 kWh, the transfers unchanged - −39.75 kWh,
short.
Fahrplan/Ist adds the change to the Regelzone’s Fahrplan (and Germany’s
by their sum), so the deviation, the Ausgleichsenergie and the Kalkulation
follow the confirmed position. Each zone says which Fahrplan it used
(fahrplan_quelle: gesendet, bestaetigt, bestaetigt_final), the
report, and the change in MWh. Confirmed as sent, nothing moves.
The alert
A confirmation that changes a trade series raisesfahrplan_vom_uenb_geaendert (High):
Amprion hat den Fahrplan 20.10. geändert (Day-Ahead, 20261020_10XDE-RWENET_CNF-DA_89253): Kauf vom Händler 39.75 → 0 kWh (A63 Die Wertereihe wurde geaendert) - Bilanzkreis in Amprion 39.75 kWh unterdecktOnce per change: the CNI and the CNF-DA a minute later with the same values say it once. A later report that holds the schedule as sent again raises
fahrplan_aenderung_aufgehoben.